Our Services
NEBS Testing
Quanta Laboratories performs NEBS testing to Telcordia GR-63-CORE, with all operational NEBS testing carried out on site. The seismic test system handles telecom racks and the test can be recorded on video.
Purpose
Demonstrate compliance with Telcordia GR-63-CORE generic requirements, the minimum criteria for telecommunication equipment systems used by Central Offices and Local Exchange Carriers.
Quanta's capabilities
- Capable of handling all NEBS testing
- All operational NEBS testing done on site
- Seismic shaker and dedicated control room
- Video camera records every test
- Large seismic test system for heavy telecom racks
- Quick turnaround on reports, accepted by all major telecom companies
Quanta's experience
Quanta works with network equipment manufacturers and testing partners to deliver complete NEBS evaluations, with an acoustically isolated control room so customers can watch their test in comfort.
How we work
Share your requirements
Send us your product details, the specification or standard you need to meet, and your timeline.
Get a recommended approach
Our engineers recommend the most efficient test method and fixturing to meet your specification.
Test in our accredited lab
Testing runs on site in Santa Clara under our ISO/IEC 17025:2017 accreditation.
Receive your report
You receive the results and test report, with engineering support to resolve any issues found.
Other services
View all services- Vibration Testing20+ electrodynamic and hydraulic shakers, up to 34,000 lbf, from 1 Hz to 500 Hz or 5 Hz to 3,000 Hz, to uncover resonant weaknesses.
- Chamber Testing30+ chambers simulate real-world temperature, humidity, altitude, and thermal shock conditions.
- Shock TestingDrop, half-sine, sawtooth, square-wave, trapezoidal and rotational shock on eight systems, up to 8,000 g.
- Package TestingPackage drop, fragility, damage boundary, bounce and stacking tests to ISTA and ASTM procedures.
- ESS HALT / HASSPatented ESS system handling racks up to 7 ft, with production line screening cycles of roughly 10 minutes.
- Battery TestingBattery safety and durability tested to UN 38.3, IEC 62133, and other global standards.
- Special TestingCustom test development for unique or non-standard applications.
- Consulting ServicesQuanta Laboratories is fully staffed with trained engineering professionals who, in addition to performing the principal testing activities, are adept at supporting our customers in the selection of the specifications needed to screen their product.